Background
A damp patch was observed on the lower ground floor of the property, which was previously affected by a leak from a washing machine. Concerns were also raised about a potential leak from a shower, located on the other side of the affected wall. During the survey, dampness was evident in the area, suggesting the presence of moisture issues related to the appliances and plumbing fixtures mentioned.
Data loggers – see damp.ai/detect

1) Dew’s Law Compliance: 79% – this is actually overstated as I only had the external data for part of the period. If you look at the internal dew point, blue, is above the external temperature about half the time. Vapour will condense when the external temperature drops below the dew point.
2) Overall Ventilation: Excellent: 0%, Good: 0%, Mediocre: 0%, Poor: 100% – your ventilation was insufficient for a majority of the time.
In conclusion, from the data loggers
- The solution is in essence simple, increase ventilation, keep the bathroom door closed, increase air movement around the damp area and use a dehumidifier whenever the dew point is close to or above the external temperature.
Evidence & Illustrations


I tested the mains water for leaks. There was no drop in pressure, when the stopcock was turned off, suggesting that there is no ongoing leak. Likewise the waste pipe from the washing machine appears to be dry.







To keep the property dry | |
|---|---|
| Use fan to expedite drying | |
| Direct a fan onto the damp patch and into the exposed sub-floor void to speed up the drying process. | |
| Improve bathroom ventilation | |
| Make sure to keep the door closed after using the shower, when there is high vapour levels. In the short-term, keep the lights on, so that the shower remains on permanently, it is running a levels similar to a continuous flow fan. Consider installing a continuous flow bathroom extractor fan such as Brookvent Airstream DMEV 100 HT (Continuous Running Extractor Fan with Humidistat Timer) – I have installed one in a rental property I own myself, that was bought cheaply because of mould. Although important to have an isolator, it can be sited in a way that doesn’t tempt tenants to use it. Ideally the vent should be located away from the door, closer to the shower. | £300 |
| Insulate pipes | |
| Insulate around water pipes, especially cold water in the sub-floor void and behind the washing machine, to reduce the risk of condensation. | £20 |
| Monitor vapour with data loggers | |
| Monitor relative humidity and temperature against the wall or ceiling to observe the effects of improvements, such as ORIA Wireless Thermometer Hygrometer (20m (2 Packs)) – already in place – use http://damp.ai/detect/ to monitor improvement over time – I will be improving it regularly. In addition monitor improvements on the damp wall a pencil line and damp meter such as dr.wood moisture meter, logging improvements each month. Monitor relative humidity and temperature against the wall or ceiling to observe the effects of improvements, such as ORIA Wireless Thermometer Hygrometer (20m (2 Packs)) – already in place. In addition monitor improvements on the damp wall with a pencil line and damp meter such as dr.wood moisture meter, logging improvements each month. | |
| Monitor sub-floor humidity | |
| Place a hygrometer probe (on Amazon, about £5, needs calibration) or data logger below the floor, near the damp wall. A probe can be inserted through floorboard cracks or by discreetly drilling a small hole. Sub-floor relative humidity tends to vary, and if it consistently remains above 85%RH over a prolonged period, consider installing a ventilation fan in the sub-floor to enhance airflow. Due to limited accessibility, increasing ventilation can be challenging. Although the company ELTA, which produced a Sub-Floor Ventilation Fan highly regarded by many clients, has ceased operations, an equivalent unit can be found here: https://www.builders-superstore.co.uk/product/ventilation-fan-sub-floor-mains-powered/. This installation will require a lengthy 100mm pipe to facilitate circular airflow in the affected area. You might also think about replacing the timber section under the stairs with a concrete floor to mitigate further risks. While some rot was present, mainly confined to the corner, it did not pose a significant health or safety issue. If the area remains dry, the risk of further damage diminishes. Ultimately, deciding on these measures is a balance of costs and benefits. Regular checks of the sub-floor data, along with inspections for rot and the structural integrity of timber using a screwdriver, are advisable. | £1,000 |
| Use a dehumidifier | |
| Maintain relative humidity, especially at night when it’s cold outside, with a dehumidifier such as PureMate 20L/Day Portable & Compact Dehumidifier with 6.5 Litre (£179.99 Refrigerant), Duux Bora Smart Dehumidifier (DXDH02UK £300 Refrigerant) or Meaco DD8L Zambezi (£260 Desiccant – best for colder environments) – Which! Best buys. There are plenty of alternatives available. I choose a dehumidifier based on daily and tank capacity, low noise, whether it has a pipe out, and ease of programmable functions over other considerations such as weight and aesthetics. The technology is old and easy to manufacture. So if these brands are not available, you are sure to find another alternative. Evaluate based on daily capacity (20L minimum) and whether it has a continuous pipe out (use this to drip into a sink when away in winter). | £180 |
| Repair grout and sealant | |
| Remove grout around cracks and regrout. Seal with silicone between a bathroom and the wall or tiles. | £100 |
| Reduce vapour from cooking | |
| Cook with tops on pots and pans to reduce the production of vapour from cooking by 80%. | |
| Remedial actions – estimate of costs | £1,600 |
Actions if all else fails | |
|---|---|
| Consider installing a kitchen extractor | |
| Ideally, kitchens should feature a quiet, user-friendly extractor fan strategically placed right above or adjacent to boiling pots and pans, ensuring vapour is efficiently expelled outdoors. Unfortunately, some installers overlook the necessity of outdoor ducting, effectively nullifying the fan’s purpose, or they opt for lengthy, flexible ducting that’s susceptible to damage and hampers airflow with its ridges and bends. To maximize the likelihood of its use, the fan’s noise level and ease of operation are crucial factors. A fan that operates quietly and automatically is more likely to be used consistently, enhancing kitchen ventilation and comfort. | £400 |
| Address penetrating damp | |
| To manage penetrating damp, consider external factors such as lowering ground levels to at least 150mm below the damp proof course and installing impermeable surfaces like concrete-based patios to direct water away from the foundation. Additionally, apply tanking materials to below-ground walls to create a waterproof barrier, using products from companies like Safeguard Europe and Sika. A practical approach is to remove shelving, fill gaps and cracks in the tanking with additional material, and possibly cover the wall with dry lining to conceal damage and reduce the risk of damp showing through. Ensure you hire a builder with proven experience in this area. | £1,500 |
| Optimal actions – estimate of costs | £1,900 |
I conclude that washing machine leak made worse by condensation from excess vapour, poor sub-floor ventilation and penetrating damp to the flank wall.
The dampness is centred on the floor level near to the bathroom and cold water pipes, both of which are at risk of condensation. The data loggers identified poor ventilation, with vapour constantly at or near the temperature where condensation takes place.
. By taking a root cause approach, rather than a focus on blocking the symptoms of damp the savings are likely to be around £10,000. This contrasts with typical damp proofing contractor recommendations such as chemical treatment for rising damp and untargeted ventilation, such as PIV systems.
Flood risk: No risk See Flood Risk (note most flood risk is not from groundwater).
Sub-soil rocks: Rocks with essentially no groundwater See British Geological Survey.
Therefore risk of Rising Damp: remote possibility, see explanation by Dr Robyn Pender of Historic England.
I confirm that I inspected the property on 240701SH1000. I conclude that washing machine leak made worse by condensation from excess vapour, poor sub-floor ventilation and penetrating damp to the flank wall.. All buildings can be exposed to unvented vapour and external dampness to some degree. You will mitigate the risk of damp if you follow all our recommendations. This report is intended to be read in full including supplementary links in this report. Observations and opinions must not be taken in isolation. Given the right weather conditions almost any house can be affected by rain. Like any building, you need to be aware of the risks of damp arising in the future and should plan a programme of monitoring, prevention and maintenance accordingly. Damp Surveys Ltd reports are designed to provide you with an informed, independent expert opinion as to the cause of dampness in the property, together with any recommendations for further investigation or remedial work. We do not warrant any findings in this report unless we enter into a separate warranty agreement with you.
The survey was conducted during daylight hours. Damp will be more noticeable at night and when the weather is colder and more humid. Gutters are more likely to fail when full of leaves and during periods of prolonged rain and adverse wind. We make best endeavours but cannot guarantee being able to identify all forms of damp, rot and insect infestation affecting the property.
We carried out a careful and thorough inspection of as much of the property as was accessible. However, when a full inspection is not possible, we make a professional judgement regarding the likelihood of a defect being present. In certain circumstances, this may lead to a recommendation for further action to open up an area for additional investigation. We were unable to inspect the entire roof, all the guttering, and some of the drains. Similarly, inspection of woodwork or other parts of the structure that were covered, unexposed, poorly lit or inaccessible such as in the loft, cellar, or sub-floor void was not possible, and therefore we are unable to assert that such parts of the property are free from defect. There were no obvious signs of damp resulting from these limitations
Negligence claims must be made within 90 days of the damp survey site visit. Clients must make best endeavours to monitor humidity and temperature on a damp wall and the closest source of humidity, by purchasing and placing two data loggers for example the Smart Hygrometer measuring humidity on the wall and nearest source of vapour, before and after following our recommendations. These data loggers have sufficient memory capacity to store 90 days of data.
This report is for the sole use of the client (named on the invoice, but omitted here for anonymity) for whom the survey was undertaken and can only be relied upon for 90 days from the survey date. Unless expressly stated otherwise in this report, nothing in this report confers or is intended to confer any rights on any third party pursuant to the Contracts (Rights of Third Parties) Act 1999.
Simon Hichens
Site visit 240701SH1000
Simon Hichens BSc Chemistry RICS Qualified Expert Witness (Chartered Surveyors)
PCA Certificated Surveyor of Dampness & Timber in Buildings (Property Care Association)
Damp Surveys Ltd, 119 Longton Ave London SE26 6RF Reg. 10977488 (England & Wales)
Founder of damp.aï & Member of the Society for the Protection of Ancient Buildings (SPAB)
Our damp surveys are designed to provide a holistic diagnosis that identifies and deals with causes rather than a focus on symptoms. Symptoms will disappear over time, once damp is stopped at source. We look for risks of dampness, but unless moisture is present, we can’t guarantee to identify all risks of future moisture. Our reports:
- identify root cause(s) of major unwanted dampness within the property,
- identify major symptoms of unwanted dampness,
- identify major structural damage caused by dampness,
- recommend actions and estimated costs to stop damp at source and mitigate its effects,
- recognise that treating damp is often a staged approach, treating obvious causes first.
Understanding damp
For survey purposes, damp is defined as unwanted water. Water brings life. We need it. Unfortunately, fungus and insects also thrive in water. While a damp wall can cause decorative spoiling, it is not moisture, but the life it brings that causes the greatest concern in the home environment. FACT: vapour causes 85% of residential damp problems.
Independence and Methodology
Our only income is through damp survey fees. We are independent of contractors and never profit from remedial work. We do not receive or pay any fees or other inducements. Our motivation is peace of mind and practical, durable solutions. We use an array of equipment to identify the root cause of damp within walls. Our damp surveys follow guidance from RICS, Historic England and PCA joint position statement and support RICS’s highest standard, level 3 “Home Survey Standard” (HSS).
During the survey we assess likelihood of rising damp*, mainswater leak, penetrating damp, condensation, timber rot and woodworm. We profile the damp patches and consider the likely sources of dampness and test ventilation against building regulations requirements. We consider changes to the property and factors just before the first sighting of damp.
“Management of moisture requires proper control of temperature and ventilation to avoid excess humidity, condensation on surfaces and excess moisture in materials. Ventilation should be distributed effectively throughout spaces, and stagnant air zones should be avoided.”
FACT: Houses contain 30 – 40 litres of water as vapour typically. Each day, each occupant adds on average about 1.5 litres as follows:
- Each shower results in 1/2L condensing (each additional shower in a series won’t add as much as the first, so long as the door is kept closed)
- Vapour from drying clothes releases about ½ litre per day if dried indoors
- Respiration releases about ¾ litre per day (of which ¼ l at night)
- Cooking produces about ¼ litre per day per person
- Unvented vapour can cause condensation, mould and allergenic dust mites. The simple rule for keeping your property dry and mould free is;
- Vent out as much vapour as produced, each and every day!
- Central heating and double-glazing reduce background ventilation. To overcome this you should use mechanical extractors. Where properties are rented, consider using monitoring devices (such as a Govee WIFI hygrometer) and if necessary, install continuous flow extractors, but beware there can be a thermal cost caused by continuous heat lost.
FACTS about Condensation and Mould
- FACT: warm air holds more water vapour than cold air. The warmer it is, the more air’s capacity to hold water vapour. Conversely the colder it is, the less capacity, until air cannot hold any more vapour. We call that the dew point or 100%RH. As soon air reaches capacity, condensation will form on the coldest surfaces.
- FACT: Mould and dust mites
- FACT: Mould only grows when air is humid for long periods. In the occupied home environment, it is 6 hours over 85% RH. For properties that are unoccupied for long periods, it is 75% RH for many days of consistent and high humidity. Avoid allowing the surface relative humidity of cold walls to exceed 85% RH by ventilating, dehumidifying, insulating, and ensuring airflow, particularly in cold corners, base of walls and ceilings, eaves, and cold window and door reveals.
- FACT: Dust mites are microscopic insects that can cause allergies. They grow in similar conditions to mould. So ventilate more to avoid allergies.
- FACT: Health concerns: There are no health and safety issues from damp noted. It is in the occupier’s interests to keep a property properly ventilated or dehumidified and temperatures above the dew and mould points throughout the property, thereby reducing the health risk associated with dust mites, bacteria, protozoans, as well as decorative spoiling caused by mould.
TIPS To Stay Condensation and Mould Free
- TIP: Reduce the production of vapour at source:
- TIP: Keep bathroom extractor fans running, or window open for at least 30 minutes.
- TIP: Keep bathroom doors closed at all times, and bathroom windows open safely.
- TIP: When filling the bath, run the cold water first then add the hot.
- TIP: Dry clothes outside, in a dryer, in a closed room with a dehumidifier or window open, never on radiators or heated rail without a door closed and a means of removing the vapour.
- TIP: Cook with tops on pots and pans, avoiding excessive boiling.
- TIP: Keep the kitchen door closed and extractor fan on where possible.
- TIP:Mechanical vents are best, but if you only have passive vents, such as a whole in the wall or chimney, then vents open with space for air to move, insulate where possible.
- TIP: Keep trickle vents open or alternatively, open windows on safety locks.
- TIP: Stop mould forming:
* Maintain external wall temperatures above 12°C, with low background heating.
* Declutter leaving space for warm air to circulate around cold surfaces.
* Where possible, avoid placing wardrobes and furniture against external walls.
* Avoid overfilling wardrobes and cupboards as it restricts air circulation.
* Use dehumidifiers or small wardrobe dehumidifying bags and replace regularly.
* Wipe mould and condensation off walls and clothes as soon as it appears. - TIP: Monitor relative humidity
* We recommend monitoring temperature and relative humidity with a data logger to see what is happening.
What does the damp report say are the main causes of damp and main actions to stop damp?
¿Qué dice el informe de humedad sobre las principales causas de la humedad y las principales acciones para detenerla?
潮湿报告说什么是潮湿的主要原因和防止潮湿的主要措施?
नमी की रिपोर्ट के अनुसार नमी के मुख्य कारण और नमी को रोकने के लिए मुख्य कार्य क्या हैं?
Que dit le rapport sur l’humidité concernant les principales causes de l’humidité et les principales actions pour l’arrêter?
Was sagt der Feuchtigkeitsbericht über die Hauptursachen von Feuchtigkeit und die Hauptmaßnahmen zur Bekämpfung von Feuchtigkeit?
Что говорится в отчете о влажности о основных причинах влажности и основных действиях по ее устранению?
Cosa dice il rapporto sull’umidità riguardo le principali cause dell’umidità e le principali azioni per fermarla?