Background
A ground floor flat in Islington, being prepared for the rental market, presented multiple damp-related challenges. Mould growth was observed in lower corners of the front external wall, alongside condensation on windows. The internal hallway exhibited mould and brown stains on the party wall, suggesting moisture ingress from the bathroom and potentially other areas. Historical damage indicative of rising damp was noted on living room skirting boards. Despite the use of vents and a dehumidifier, bathroom moisture remained, exacerbated by blocked grouting and a lack of sufficient ventilation.
High humidity levels were confirmed through dew point measurements, with the absence of a kitchen extractor fan and indoor clothes drying contributing to the issue. Cold zones, especially near the sub-floor vent, were identified as increasing surface relative humidity and the risk of mould and condensation at the wall base.
Data loggers




Conclusion, from the data loggers
- Overall the vapour levels are too high. The bathroom should be better. It can take months 9 months for walls to dry out.
- The kitchen needs improving, especially if you wish to rent the property out. Building regulations (regs) require a fan with at least 30 litres per second (l/s). An over hob hood works best for targeting vapour. Make it a requirement for tenants to use the fan.
- I would upgrade your dehumidifier and use a fan to speed up the drying process.
Evidence & Illustrations




To keep the property dry | |
|---|---|
| Fill render cracks | |
| Check and repair any cracks in the exterior walls to prevent water ingress. Address external render cracks by raking out, that is slightly enlarging and removing loose material and filling with an acrylic based caulk for small gaps and cement based mortar for larger gaps over 3mm. Paint over cracks and previously painted cracks with an impermeable paint, such as Zinsser or Dulux external impermeable masonry paint, avoid semi-permeable paints, they don’t stop water entering cracks. This should be done for the whole property. I am assuming two days work, divided. It may cost more if scaffolding or a platform is required. | £500 |
| Use a dehumidifier | |
| Maintain relative humidity, especially at night when it’s cold outside, with a dehumidifier such as PureMate 20L/Day Portable & Compact Dehumidifier with 6.5 Litre (£179.99 Refrigerant), Duux Bora Smart Dehumidifier (DXDH02UK £300 Refrigerant) or Meaco DD8L Zambezi (£260 Desiccant – best for colder environments) – Which! Best buys. There are plenty of alternatives available. I choose a dehumidifier based on daily and tank capacity, low noise, whether it has a pipe out, and ease of programmable functions over other considerations such as weight and aesthetics. The technology is old and easy to manufacture. So if these brands are not available, you are sure to find another alternative. Evaluate based on daily capacity (20L minimum) and whether it has a continuous pipe out (use this to drip into a sink when away in winter). | £180 |
| Use fan to expedite drying | |
| Direct a fan onto the damp patch to speed up the drying process. | |
| Monitor vapour with data loggers | |
| Monitor relative humidity and temperature against the wall or ceiling to observe the effects of improvements, such as ORIA Wireless Thermometer Hygrometer (20m (2 Packs)) – already in place. In addition monitor improvements on the damp wall a pencil line and damp meter such as dr.wood moisture meter, logging improvements each month. Monitor relative humidity and temperature against the wall or ceiling to observe the effects of improvements, such as ORIA Wireless Thermometer Hygrometer (20m (2 Packs)) – already in place. Aim to keep dew points at or below the outside temperature, as a well ventilated property should be. In addition monitor improvements on the damp wall with a pencil line and damp meter such as dr.wood moisture meter, logging improvements each month. | |
| Consider blocking sub-floor airbricks | |
| Consider blocking and insulating the front sub-floor airbricks such as this sub-floor air brick covers developed for flood protection. This is not instead of dropping the dew point to external temperatures through improved ventilation and dehumidification. It is important to monitor sub-floor humidity. Use a hygrometer probe under internal rear airbrick. The sub-floor relative humidity will fluctuate. If it remains above 85%RH for an extended period then 1) open the air vent, 2) check for a leaks, see my videos on doing this. Check sub-floor weekly. Ask a tenant to send weekly photos. | |
| Reduce vapour from cooking | |
| Cook with tops on pots and pans to reduce the production of vapour from cooking by 80%. | |
| Remove mould | |
| Consider sanding down mould where dry, and removing it with either bleach or anti-mould foam. I personally use HG Mould Remover Foam Spray, but imagine there is no major difference between brands. | £100 |
| Bathroom Humidity Management | |
| After showering, keep the bathroom door closed and the window open or fan running for at least 30 minutes to allow vapour to dissipate. | |
| Target vapour from clothes drying | |
| Use a tumble dryer (like a heat pump), dry in a vented room with the door closed (possibly a bathroom with the extractor running or window open), or use a powerful dehumidifier. Don’t dry clothes in an unventilated room. While there is no legal requirement to provide drying facilities for tenants, think of a good solution, which could include a drying rack in the bathroom or probably better a dehumidifier with instructions to always use it when drying clothe or internal humidity and or dew points are too high. | |
| Insulate pipes | |
| Insulate around all water pipes, especially cold water, also consider insulating the wall under the cupboard and behind the kitchen units. | £10 |
| Remedial actions – estimate of costs | £790 |
Actions if all else fails | |
|---|---|
| Consider installing a kitchen extractor | |
| Ideally, kitchens should feature a quiet, user-friendly extractor fan strategically placed right above or adjacent to boiling pots and pans, ensuring vapour is efficiently expelled outdoors. Unfortunately, some installers overlook the necessity of outdoor ducting, effectively nullifying the fan’s purpose, or they opt for lengthy, flexible ducting that’s susceptible to damage and hampers airflow with its ridges and bends. To maximize the likelihood of its use, the fan’s noise level and ease of operation are crucial factors. A fan that operates quietly and automatically is more likely to be used consistently, enhancing kitchen ventilation and comfort. | £600 |
| Consider replacing the bathroom extractor | |
| In my opinion, the optimal fans are ones that are targeted, with the fan located near the shower head (without being so close that water sprays onto it), removing vapour during and for at least 30 minutes after taking a shower or bath (which typically produces slightly less vapour). Ideally the fan should be separately wired up with an overrun. Installing the overrun can account for a majority of the cost. Consider installing a continuous flow extractor fan such as Brookvent Airstream DMEV 100 HT (Continuous Running Extractor Fan with Humidistat Timer). Note a continuous flow fan will expel warm air, thereby increasing heating cost by about £120 p.a. but this may be a small price to pay. You can use an isolator to manually turn off the fan when the property is sufficiently ventilated, but the risk is it is left off. | £400 |
| Improve tenancy agreement | |
| Ask for the tenancy agreement to require tenants understanding of and compilance with good ventilation and therefore vapour management, see Tenants responsibility to stay mould and damp free, or at least communicate to tenants their responsibilities, and praise them for already communicating. Dealing with damp and mould requires teamwork, communication and appreciation that it is not always easy for tenants, nor do they necessarily understand their challenges and responsibilities. | |
| Consider remotely monitoring humidity | |
| You can use WIFI connected dataloggers, the only issue is they need a WIFI connection, which requires the tenant to provide WIFI access which can be fiddly. An alternative is to ask the tenant to send data, or possibly better is to use a Nest which has the humidity and temperature (which also requires access, but would less fiddly, with fewer battery issues), from which you can access data and work out the dew point, see mouldpoint.co.uk for a calculation for dew point, forecast dew point max and surface relative humidity. | £50 |
| Consider targeted insulation | |
| It is better to use vapour active insulation, such as Woodfibre, when above timber to reduce the risk of condensation forming within the wall risking rot in timber below. Thermal insulating lining paper, such as by Wallrock is another good solution. | £1,000 |
| Optimal actions – estimate of costs | £2,050 |
I conclude that there was no evidence of rising damp, which comes from groundwater in contact with walls. The risk of groundwater is very low. There were many signs of excess humidity causing condensation and mould, made worse by heat loss.
Mould grows where relative humidity exceeds 85%RH. Relative humidity is a function of temperature and vapour. Heat loss, such as from metal and sub-floor air vents increase the relative humidity and risk of mould and condensation.
The bathroom extractor fan was more or less completely blocked by excessive flexible ducting. I shorted it, clean the fan up. It should now work according to manufacturers specifications.. By taking a root cause approach, rather than a focus on blocking the symptoms of damp the savings are likely to be around £10,000. This contrasts with typical damp proofing contractor recommendations such as chemical treatment for rising damp and untargeted ventilation, such as PIV systems.
Flood risk: No risk See Flood Risk (note most flood risk is not from groundwater).
Sub-soil rocks: Rocks with essentially no groundwater See British Geological Survey.
Therefore risk of Rising Damp: remote possibility, see explanation by Dr Robyn Pender of Historic England.
I confirm that I inspected the property on 240130SH1200. I conclude that there was no evidence of rising damp, which comes from groundwater in contact with walls. the risk of groundwater is very low. there were many signs of excess humidity causing condensation and mould, made worse by heat loss. All buildings can be exposed to unvented vapour and external dampness to some degree. You will mitigate the risk of damp if you follow all our recommendations. This report is intended to be read in full including supplementary links in this report. Observations and opinions must not be taken in isolation. Given the right weather conditions almost any house can be affected by rain. Like any building, you need to be aware of the risks of damp arising in the future and should plan a programme of monitoring, prevention and maintenance accordingly. Damp Surveys Ltd reports are designed to provide you with an informed, independent expert opinion as to the cause of dampness in the property, together with any recommendations for further investigation or remedial work. We do not warrant any findings in this report unless we enter into a separate warranty agreement with you.
The survey was conducted during daylight hours. Damp will be more noticeable at night and when the weather is colder and more humid. Gutters are more likely to fail when full of leaves and during periods of prolonged rain and adverse wind. We make best endeavours but cannot guarantee being able to identify all forms of damp, rot and insect infestation affecting the property.
We carried out a careful and thorough inspection of as much of the property as was accessible. However, when a full inspection is not possible, we make a professional judgement regarding the likelihood of a defect being present. In certain circumstances, this may lead to a recommendation for further action to open up an area for additional investigation. We were unable to inspect the entire roof, all the guttering, and some of the drains. Similarly, inspection of woodwork or other parts of the structure that were covered, unexposed, poorly lit or inaccessible such as in the loft, cellar, or sub-floor void was not possible, and therefore we are unable to assert that such parts of the property are free from defect. There were no obvious signs of damp resulting from these limitations
Negligence claims must be made within 90 days of the damp survey site visit. Clients must make best endeavours to monitor humidity and temperature on a damp wall and the closest source of humidity, by purchasing and placing two data loggers for example the Smart Hygrometer measuring humidity on the wall and nearest source of vapour, before and after following our recommendations. These data loggers have sufficient memory capacity to store 90 days of data.
This report is for the sole use of the client (named on the invoice, but omitted here for anonymity) for whom the survey was undertaken and can only be relied upon for 90 days from the survey date. Unless expressly stated otherwise in this report, nothing in this report confers or is intended to confer any rights on any third party pursuant to the Contracts (Rights of Third Parties) Act 1999.
Simon Hichens
Site visit 240130SH1200
Simon Hichens BSc Chemistry RICS Qualified Expert Witness (Chartered Surveyors)
PCA Certificated Surveyor of Dampness & Timber in Buildings (Property Care Association)
Damp Surveys Ltd, 119 Longton Ave London SE26 6RF Reg. 10977488 (England & Wales)
Founder of damp.aï & Member of the Society for the Protection of Ancient Buildings (SPAB)
Our damp surveys are designed to provide a holistic diagnosis that identifies and deals with causes rather than a focus on symptoms. Symptoms will disappear over time, once damp is stopped at source. We look for risks of dampness, but unless moisture is present, we can’t guarantee to identify all risks of future moisture. Our reports:
- identify root cause(s) of major unwanted dampness within the property,
- identify major symptoms of unwanted dampness,
- identify major structural damage caused by dampness,
- recommend actions and estimated costs to stop damp at source and mitigate its effects,
- recognise that treating damp is often a staged approach, treating obvious causes first.
Understanding damp
For survey purposes, damp is defined as unwanted water. Water brings life. We need it. Unfortunately, fungus and insects also thrive in water. While a damp wall can cause decorative spoiling, it is not moisture, but the life it brings that causes the greatest concern in the home environment. FACT: vapour causes 85% of residential damp problems.
Independence and Methodology
Our only income is through damp survey fees. We are independent of contractors and never profit from remedial work. We do not receive or pay any fees or other inducements. Our motivation is peace of mind and practical, durable solutions. We use an array of equipment to identify the root cause of damp within walls. Our damp surveys follow guidance from RICS, Historic England and PCA joint position statement and support RICS’s highest standard, level 3 “Home Survey Standard” (HSS).
During the survey we assess likelihood of rising damp*, mainswater leak, penetrating damp, condensation, timber rot and woodworm. We profile the damp patches and consider the likely sources of dampness and test ventilation against building regulations requirements. We consider changes to the property and factors just before the first sighting of damp.
- Rising damp concern: You were concern you might have rising damp.
- Damp treatment: Given the way walls are behaving and disruption at the external base of walls, I suspect there has been some chemical rising damp proofing treatment in the past. Rising damp treatment is normally a sign of insufficient ventilation. Normal absorbent plaster is typically replaced with impermeable damp proofers slurry. This can cause problems with absorption imbalance, resulting in increased condensation on other walls or vapour becoming absorbed and trapped behind the slurry. There was evidence of surface condensation in areas probably not treated with replacement plaster but no evidence of trapped vapour. The solution is through ventilation and humidity control.
- Weather: dry overcast
- Property: Victorian ground floor flat
- Background: Mould and moisture in a few places in our ground floor flat.
- Changes: conversion into flats, central heating and lifestyle changes including more frequent showers and clothes washing, including greater occupancy during the Covid pandemic.
- Occupancy: owner occupied
- Mould & notes: mould in bedroom mainly
- Primary damp concern: mould and dampness at the base of walls
- Other damp concerns: dampness around bathroom
- Compounding: heat loss through metal work and sub-floor ventilation
- Airbricks: Sub-floor air bricks are precautionary, to evaporate away a unnoticed water, thereby reducing the risk of rot. The sub-floor airbricks air bricks have been opened up to the kitchen, creating a risk of vapour condensing the sub-floor.
- Sub-floor humidity: The sub-floor had normal levels of relative humidity, but given the risk, the sub-floor humidity should be monitored. Better still insulate it making sure to monitor humidity every few weeks, this can be done electronically with a WIFI connected data logger.
- Tenure: ground floor flat
- Attachment: a terraced
- Build: Victorian
- Walls: solid wall made of two brick widths (225mm)
- Exterior comment: there are cracks in external render, but no corresponding damp stain seen internally.
- Penetrating damp assessment: Heat loss caused by rainwater penetrating the outer skin of bricks, could reduce heat increasing the risk of condensation.
- Drains: The drains seem to function correctly.
- Leak signs: No suspicion of a mains water leak
- Leak assessment: There are no obvious signs of a significant mains or wastewater leak.
- Floor: The suspended timber floor did not feel damaged.
- Loft: There was no loft.
- Timber assessment: There are no suspicions of significant timber decay.
- Last dry: I understand that some damp issues were picked up when you bought, but these have become worse over time.
- Ventilation assessment: The kitchen has no ventilation. The bathroom ventilation was poor. I have improved it.
W.H.O. indoor air quality guidelines
“Management of moisture requires proper control of temperature and ventilation to avoid excess humidity, condensation on surfaces and excess moisture in materials. Ventilation should be distributed effectively throughout spaces, and stagnant air zones should be avoided.”
FACT: Houses contain 30 – 40 litres of water as vapour typically. Each day, each occupant adds on average about 1.5 litres as follows:
- Each shower results in 1/2L condensing (each additional shower in a series won’t add as much as the first, so long as the door is kept closed)
- Vapour from drying clothes releases about ½ litre per day if dried indoors
- Respiration releases about ¾ litre per day (of which ¼ l at night)
- Cooking produces about ¼ litre per day per person
- Unvented vapour can cause condensation, mould and allergenic dust mites. The simple rule for keeping your property dry and mould free is;
- Vent out as much vapour as produced, each and every day!
- Central heating and double-glazing reduce background ventilation. To overcome this you should use mechanical extractors. Where properties are rented, consider using monitoring devices (such as a Govee WIFI hygrometer) and if necessary, install continuous flow extractors, but beware there can be a thermal cost caused by continuous heat lost.
FACTS about Condensation and Mould
- FACT: warm air holds more water vapour than cold air. The warmer it is, the more air’s capacity to hold water vapour. Conversely the colder it is, the less capacity, until air cannot hold any more vapour. We call that the dew point or 100%RH. As soon air reaches capacity, condensation will form on the coldest surfaces.
- FACT: Mould and dust mites
- FACT: Mould only grows when air is humid for long periods. In the occupied home environment, it is 6 hours over 85% RH. For properties that are unoccupied for long periods, it is 75% RH for many days of consistent and high humidity. Avoid allowing the surface relative humidity of cold walls to exceed 85% RH by ventilating, dehumidifying, insulating, and ensuring airflow, particularly in cold corners, base of walls and ceilings, eaves, and cold window and door reveals.
- FACT: Dust mites are microscopic insects that can cause allergies. They grow in similar conditions to mould. So ventilate more to avoid allergies.
- FACT: Health concerns: There are no health and safety issues from damp noted. It is in the occupier’s interests to keep a property properly ventilated or dehumidified and temperatures above the dew and mould points throughout the property, thereby reducing the health risk associated with dust mites, bacteria, protozoans, as well as decorative spoiling caused by mould.
TIPS To Stay Condensation and Mould Free
- TIP: Reduce the production of vapour at source:
- TIP: Keep bathroom extractor fans running, or window open for at least 30 minutes.
- TIP: Keep bathroom doors closed at all times, and bathroom windows open safely.
- TIP: When filling the bath, run the cold water first then add the hot.
- TIP: Dry clothes outside, in a dryer, in a closed room with a dehumidifier or window open, never on radiators or heated rail without a door closed and a means of removing the vapour.
- TIP: Cook with tops on pots and pans, avoiding excessive boiling.
- TIP: Keep the kitchen door closed and extractor fan on where possible.
- TIP:Mechanical vents are best, but if you only have passive vents, such as a whole in the wall or chimney, then vents open with space for air to move, insulate where possible.
- TIP: Keep trickle vents open or alternatively, open windows on safety locks.
- TIP: Stop mould forming:
* Maintain external wall temperatures above 12°C, with low background heating.
* Declutter leaving space for warm air to circulate around cold surfaces.
* Where possible, avoid placing wardrobes and furniture against external walls.
* Avoid overfilling wardrobes and cupboards as it restricts air circulation.
* Use dehumidifiers or small wardrobe dehumidifying bags and replace regularly.
* Wipe mould and condensation off walls and clothes as soon as it appears. - TIP: Monitor relative humidity
* We recommend monitoring temperature and relative humidity with a data logger to see what is happening.