Background
The damp issue observed in the corner of the sitting room, which faces the street and is located adjacent to the front door, is believed to be influenced by several factors. Previously, damp proofing treatment had been applied to this area, suggesting a history of moisture-related concerns. Additionally, a mains water leak outside the property has been identified, potentially contributing to the problem.
Data loggers


In conclusion, from the data loggers
- Condensation was not a factor on the front sitting room wall, but in my opinion it is the root cause of dampness in the bathroom, there being insufficient ventilation, no brown staining, normally associated with a leak, and penetrating damp and no clear defect on the outside.
Evidence & Illustrations








To keep the property dry | |
|---|---|
| Use fan to expedite drying | |
| The main area of dampness by the door on the front wall should dry up on its own accord now that the leak has been repaired. Direct a fan towards any damp areas to expedite the drying process. Monitor dampness, once dry, rub away surface salts, they are benign, then paint possibly after using filler or applying finishing plaster. | |
| Monitor improvements | |
| Mark improvements on damp walls with a pencil line or sticky note and use a moisture meter, such as the Dr. Meter Wood Moisture Meter 2 in 1 Pin & Pinless Multifunctional Water Detector £23.99 or similar damp meter, to log and monitor reduction to dampness in walls. By doing so, you will gain early confidence in these recommendations. Use devices like the ORIA Wireless Thermometer Hygrometer to monitor relative humidity and temperature near walls or ceilings, look to keep the dew point at or below the external temperature. The dew point is shown on the app (if not use https://mouldpoint.co.uk to calculate the dew point from humidity and temperature readings). | |
| Clear gutter | |
| Ask your righthand neighbour (as seen from the street) to clear their gutter of plants. You may have a legal right to clear them yourself, if they won’t cooperate. | £100 |
| Monitor sub-floor humidity | |
| Use the hygrometer probe, humidity meter with long wire, I left under the floor. It was normal during the survey at 66%RH. The sub-floor relative humidity may fluctuate. In the unlikely event that it rises, remaining above 85%RH for an extended period then consider increasing sub-floor ventilation. Ventilation is tricky as there is limited access. A company called ELTA made a Sub-Floor Ventilation Fan, which many clients with similar issues have installed with success, but ELTA have been closed down. This site seems to offer the same unit: https://www.builders-superstore.co.uk/product/ventilation-fan-sub-floor-mains-powered/ you could also dry air out with a dehumidifier, blowing air from the sub-floor into the cellar, then drying it. | £5 |
| Repaint external wall | |
| Wire brush the paint on the external walls back to brick, as much as possible at least to remove the surface salts. Then use a paint that is as impermeable, ideally the same as the existing paint, or more impermeable, such as Zinsser or Dulux external masonry paint. | |
| Use a dehumidifier | |
| To manage relative humidity, especially when poorly ventilated, humid or cold, consider using a dehumidifier such as the PureMate 20L/Day Portable & Compact Dehumidifier with 6.5 Litre (£179.99 Refrigerant), Duux Bora Smart Dehumidifier (DXDH02UK £300 Refrigerant) or Meaco DD8L Zambezi (£260 Desiccant – optimal for colder environments) – all highly rated by Which!. There are numerous alternatives if these specific models are not available. When selecting a dehumidifier, prioritise factors like daily and tank capacity, low noise levels, the availability of a continuous drainage option, and ease of use for programming functions, over aesthetics and weight. The technology behind dehumidifiers is well-established and straightforward to produce, ensuring you can find a suitable alternative focusing on a minimum daily capacity of 20L and the presence of a continuous drainage feature. | £180 |
| Target vapour from bathroom | |
| TIP: Keep the bathroom door closed with the fan running or window open until the humidity from the shower has subsided – typically at least 30 mins after the last shower. | |
| Duct out the top bathroom vent | |
| The top bathroom vent is ducted into the roof void, risking mould, dampness and rot. It should be ducted out. This can be done into the eaves. Make sure that air is properly leaving the property (don’t take a builder’s word for it, check, consider using an anemometer on the end of a pole to check that air is flowing outside and not into the loft). Once done then you should increase the bathroom extractor fan overrun. See other example of damp survey films. It is relatively easy, typically you have to leaver the cover off and turn a dial. | £300 |
| Target vapour from clothes drying | |
| Opt for a tumble dryer, dry laundry in a well-ventilated room with the door closed (such as a bathroom with the extractor fan on or window open), or employ a sufficiently high capacity dehumidifier. Avoid drying clothes in poorly ventilated areas and anywhere near cold walls. | |
| Target vapour from cooking | |
| Always use tops on pots and pans to reduce vapour emission by 80% and where applicable use an externally ducted kitchen extractor fan. | |
| Remedial actions – estimate of costs | £585 |